Review




Structured Review

abberior instruments abberior stedycon microscope
Abberior Stedycon Microscope, supplied by abberior instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/abberior+stedycon+microscope/stedycon+microscope/pm40343993-291-15-18
Average 90 stars, based on 1 article reviews
abberior stedycon microscope - by Bioz Stars, 2026-10
90/100 stars

Images

Related Articles

Microscopy:

Article Title: Acute chromatin decompaction stiffens the nucleus as revealed by nanopillar-induced nuclear deformation in cells.
Article Snippet: .. High- resolution microscopy of H3K27me3 foci were performed on Hela cells by imaging on the Abberior STEDycon microscope (Abberior Instruments GmbH) equipped with pulsed STED line at 775 nm, excitation lasers at 485 and 640 nm with 100 nm pixel size and 100× oil immersion objective (NA = 1.4). ..

Article Title: Exosomes Recovered From the Plasma of COVID-19 Patients Expose SARS-CoV-2 Spike-Derived Fragments and Contribute to the Adaptive Immune Response.
Article Snippet: Vesicle-coated beads were washed and seeded onto glass coverslips (n. 1.5 thickness; electron microscopy), then stained with anti-SARS-CoV-2-S RBD (1:500), followed by hybridization with secondary antibodies conjugated with the Star*RED fluorophore (Abberior; 1:200), and finally mounted onto glass slides with ProlongGlass mounting reagent for super-resolution (Molecular Probes, Thermo Fisher Scientific). .. Samples were January 2022 | Volume 12 | Article 785941 acquired using a demo version of the Abberior STEDYCON microscope for simultaneous confocal and STED microscopy (kind collaboration with Abberior Instrument) with 4 excitation laser lines and a 775-nm depletion STED laser. ..

Article Title: TMEM123 a key player in immune surveillance of colorectal cancer.
Article Snippet: Samples were mounted onto glass-slides with ProlongGlass mounting reagent for super-resolution (Molecular Probes, ThermoFisher Scientific). .. Samples were acquired using an Abberior STEDYCON microscope (Abberior Instruments, Germany) for simultaneous confocal and STED microscopy, equipped with a 60x TIRF oil objective (NA 1.49), mounted on an inverted Olympus IX73 microscope, with XY precision stage (Marzhauser, Germany) and Z-stage (PiezoConcept, Germany), with 4 excitation laser lines (405, 488, 561, 640nm) and a 775 nm depletion STED laser (system integrated by Crisel Instruments, Italy). ..

Article Title: Folate depletion induces erythroid differentiation through perturbation of de novo purine synthesis.
Article Snippet: Coverslips were mounted onto glass slides using ProLong Gold Antifade Mountant (Thermo Fisher Scientific, P36930). .. Images were acquired using Abberior STEDYCON microscope. ..

Article Title: An aldehyde-crosslinking mitochondrial probe for STED imaging in fixed cells
Article Snippet: .. Neonatal rat cardiomyocytes: 600 nM PKMO FX, 1h.101 Neuron cells: 400 nM PKMO FX, 0.5 h. FH-proficient cells and FH-deficient cells: 650 nM102 PKMO FX, 10 μM verapamil, 2 h.103 Fig. 4b : 600 nM PKMO FX, 200 nM Halo-SiR, 8 μM verapamil,1 h.104 Fig. 4c-e : 600 nM PKMO FX, 8 μM verapamil,1 h.105 Fig. 4g, Fig. 5, Fig. 6: Shown in the metabolic labeling, immunolabeling and CLEM parts106 respectively.107 108 STED and confocal imaging109 Partial images (Fig 2a-e; Fig 3a; Fig 4 b-e; Fig 5b; Fig S1-S7a; Fig S9-S12; Fig S14-S15) were110 taken on an Abberior STEDYCON microscope (Abberior Instruments GmbH, Göttingen,111 Germany) equipped with a 100×/1.45 oil objective (Nikon, Tokyo, Japan). ..

Article Title: Functional Delineation of a Protein–Membrane Interaction Hotspot Site on the HIV-1 Neutralizing Antibody 10E8
Article Snippet: .. STED images were acquired using an Abberior STEDYCON microscope (Abberior Instruments, Göttingen, Germany) attached to an Olympus IX83 inverted microscope body (Olympus, Tokyo, Japan) equipped with a 100×/1.40 NA UPlanSApo Olympus objective lens. mCherry was excited with a 561 nm laser and STAR RED with a 640 nm laser. ..

Article Title: Exosomes Recovered From the Plasma of COVID-19 Patients Expose SARS-CoV-2 Spike-Derived Fragments and Contribute to the Adaptive Immune Response
Article Snippet: Vesicle-coated beads were washed and seeded onto glass coverslips (n. 1.5 thickness; electron microscopy), then stained with anti-SARS-CoV-2-S RBD (1:500), followed by hybridization with secondary antibodies conjugated with the Star*RED fluorophore (Abberior; 1:200), and finally mounted onto glass slides with ProlongGlass mounting reagent for super-resolution (Molecular Probes, Thermo Fisher Scientific). .. Samples were acquired using a demo version of the Abberior STEDYCON microscope for simultaneous confocal and STED microscopy (kind collaboration with Abberior Instrument) with 4 excitation laser lines and a 775-nm depletion STED laser. ..

Imaging:

Article Title: Acute chromatin decompaction stiffens the nucleus as revealed by nanopillar-induced nuclear deformation in cells.
Article Snippet: .. High- resolution microscopy of H3K27me3 foci were performed on Hela cells by imaging on the Abberior STEDycon microscope (Abberior Instruments GmbH) equipped with pulsed STED line at 775 nm, excitation lasers at 485 and 640 nm with 100 nm pixel size and 100× oil immersion objective (NA = 1.4). ..

Labeling:

Article Title: An aldehyde-crosslinking mitochondrial probe for STED imaging in fixed cells
Article Snippet: .. Neonatal rat cardiomyocytes: 600 nM PKMO FX, 1h.101 Neuron cells: 400 nM PKMO FX, 0.5 h. FH-proficient cells and FH-deficient cells: 650 nM102 PKMO FX, 10 μM verapamil, 2 h.103 Fig. 4b : 600 nM PKMO FX, 200 nM Halo-SiR, 8 μM verapamil,1 h.104 Fig. 4c-e : 600 nM PKMO FX, 8 μM verapamil,1 h.105 Fig. 4g, Fig. 5, Fig. 6: Shown in the metabolic labeling, immunolabeling and CLEM parts106 respectively.107 108 STED and confocal imaging109 Partial images (Fig 2a-e; Fig 3a; Fig 4 b-e; Fig 5b; Fig S1-S7a; Fig S9-S12; Fig S14-S15) were110 taken on an Abberior STEDYCON microscope (Abberior Instruments GmbH, Göttingen,111 Germany) equipped with a 100×/1.45 oil objective (Nikon, Tokyo, Japan). ..

Immunolabeling:

Article Title: An aldehyde-crosslinking mitochondrial probe for STED imaging in fixed cells
Article Snippet: .. Neonatal rat cardiomyocytes: 600 nM PKMO FX, 1h.101 Neuron cells: 400 nM PKMO FX, 0.5 h. FH-proficient cells and FH-deficient cells: 650 nM102 PKMO FX, 10 μM verapamil, 2 h.103 Fig. 4b : 600 nM PKMO FX, 200 nM Halo-SiR, 8 μM verapamil,1 h.104 Fig. 4c-e : 600 nM PKMO FX, 8 μM verapamil,1 h.105 Fig. 4g, Fig. 5, Fig. 6: Shown in the metabolic labeling, immunolabeling and CLEM parts106 respectively.107 108 STED and confocal imaging109 Partial images (Fig 2a-e; Fig 3a; Fig 4 b-e; Fig 5b; Fig S1-S7a; Fig S9-S12; Fig S14-S15) were110 taken on an Abberior STEDYCON microscope (Abberior Instruments GmbH, Göttingen,111 Germany) equipped with a 100×/1.45 oil objective (Nikon, Tokyo, Japan). ..

Inverted Microscopy:

Article Title: Functional Delineation of a Protein–Membrane Interaction Hotspot Site on the HIV-1 Neutralizing Antibody 10E8
Article Snippet: .. STED images were acquired using an Abberior STEDYCON microscope (Abberior Instruments, Göttingen, Germany) attached to an Olympus IX83 inverted microscope body (Olympus, Tokyo, Japan) equipped with a 100×/1.40 NA UPlanSApo Olympus objective lens. mCherry was excited with a 561 nm laser and STAR RED with a 640 nm laser. ..



Similar Products

90
abberior instruments abberior stedycon microscope
Abberior Stedycon Microscope, supplied by abberior instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/abberior+stedycon+microscope/stedycon+microscope/pm40343993-291-15-18
Average 90 stars, based on 1 article reviews
abberior stedycon microscope - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results